Skip to content

Pole Pairs vs Poles: Why It Matters for Commutation

Knowledge & Insights

Introduction

Set the wrong pole count and your motor runs at exactly twice or half the speed you asked for. The two terms behind that mistake are poles and pole pairs, and they are not the same number.

A pole is one magnetic pole on the rotor. A pole pair is two of them, one north and one south. The pole count is always even, so pole pairs are simply the pole count divided by two. Get this number right and commutation lines up with the rotor. Get it wrong and the controller drives the motor at the wrong speed.

Poles vs Pole Pairs: The Definition

The poles are the actual magnetic poles on the rotor. A rotor with four magnets arranged as north, south, north, south has four poles. Magnets come in north and south, so poles always show up in even numbers. You never have a motor with three or five poles.

A pole pair is one north pole plus the matching south pole next to it. One full magnetic cycle, north to south and back, is one pole pair. So the relationship is simple:

pole pairs = poles / 2

A 2-pole motor has 1 pole pair. An 8-pole motor has 4 pole pairs. The pole pair number is what most controller settings actually care about, because the controller drives one electrical cycle per pole pair.

PolesPole pairsElectrical turnsMechanical turns
2111
4221
6331
8441
12661

Labeled brushless motor cutaway showing rotor, stator, and Hall effect sensor

Takeaway: poles are the magnets you can count, pole pairs are that number halved, and the controller usually works in pole pairs.

Electrical vs Mechanical Angle

A motor has two kinds of angle, and mixing them up is where most pole confusion starts. The mechanical angle is the real physical position of the shaft. One mechanical turn is 360 mechanical degrees, the shaft back where it started.

Schematic: a four-pole rotor (two pole pairs) and how one mechanical turn equals two electrical cycles.

The electrical angle tracks the magnetic field, not the shaft. The controller energizes the windings in step with the field, so it thinks in electrical degrees. One electrical turn is 360 electrical degrees, one full pass through a single pole pair.

Why One Mechanical Turn Is Several Electrical Turns

The field repeats once per pole pair, so the electrical angle spins faster than the shaft. The link is direct:

electrical turns = pole pairs x mechanical turns

On a 2-pole motor (1 pole pair), one shaft turn is one electrical turn. They match. On an 8-pole motor (4 pole pairs), one shaft turn is four electrical turns. The controller commutes through the magnetic pattern four times while the shaft goes around once. This is why a position sensor reading must be scaled by the pole pair count before the controller can use it for commutation.

Takeaway: the shaft and the field only agree on a 2-pole motor. On every other motor, the field turns faster by the pole pair factor.

Why It Matters for Commutation

Commutation is the act of switching current into the right windings at the right moment so the field keeps pulling the rotor. To do that, the controller has to know how the electrical angle maps to the shaft, and that map is set entirely by the pole pair count.

Commutation Frequency and Speed

The electrical frequency the controller produces scales with pole pairs. For a given mechanical speed:

electrical frequency (Hz) = pole pairs x mechanical speed (rev/s)

A 4-pole-pair motor spinning at 3,000 rpm (50 rev/s) needs an electrical frequency of 200 Hz. The same shaft speed on a 1-pole-pair motor needs only 50 Hz. More pole pairs generally mean a higher electrical frequency at the same rpm, which the controller and its PWM stage have to keep up with. This is one reason high-pole-count direct-drive motors run at modest rpm but still demand fast switching.

What Goes Wrong If You Get It Wrong

If you tell the controller the wrong number, the electrical-to-mechanical map is off and the motor misbehaves in predictable ways:

  • Pole pairs entered as poles (double the real value): the controller thinks it needs twice the electrical turns, so the shaft typically runs at half the commanded speed.
  • Poles entered as pole pairs (half the real value): the shaft typically runs at double the commanded speed.
  • A value that is far off: commutation falls out of sync with the rotor, torque drops, the motor stutters, draws extra current, or fails to start.

Takeaway: the pole pair number is the conversion factor between what you command and what the shaft does. A wrong value usually shows up first as the wrong speed.

Three-phase sine waveforms spaced 120 degrees apart, one electrical cycle

How to Find and Set It

You can read the pole or pole pair count straight from the motor datasheet, where it is listed as “poles”, “number of poles”, or “pole pairs”. Check which one the sheet means, then convert if needed with pole pairs = poles / 2. If there is no datasheet, you can count the magnets on the rotor, or measure it. Many controllers, including SOLO, can find the pole count for you during motor identification. If you are matching the pole count to a feedback device, our overview of motor encoders covers how the sensor ties into commutation.

Takeaway: read it from the datasheet, count the magnets, or let the controller identify it, then enter the value the controller asks for.

How SOLO Covers Pole Pairs Setup

SOLO controllers handle the pole setting either way: you can enter the value yourself or let automatic motor identification detect it, so the electrical angle maps to the shaft without manual math. You can set it from the SOLO Motion Terminal on any SOLO motor controller.

Conclusion

Poles are the magnetic poles on the rotor, always an even number, and pole pairs are that count divided by two. The pole pair number sets how the electrical angle maps to the shaft: one mechanical turn equals pole pairs electrical turns, and electrical frequency scales with pole pairs. That is why the value drives commutation, and why a wrong entry shows up as a motor running at double or half speed. Read the count from the datasheet or let the controller identify it, then enter it in the Motion Terminal so commutation stays in sync.

FAQ

What is the difference between poles and pole pairs?

Poles are the individual magnetic poles on the rotor, counted one by one, and the total is always even. A pole pair is one north pole plus its matching south pole. So pole pairs are the pole count divided by two: a 6-pole motor has 3 pole pairs.

How do I convert poles to pole pairs?

Divide the pole count by two. Pole pairs = poles / 2. To go the other way, multiply pole pairs by two to get poles. A 4-pole motor has 2 pole pairs, and 2 pole pairs means 4 poles.

Why do pole pairs affect motor speed?

The controller drives one electrical cycle per pole pair, so the field turns faster than the shaft by the pole pair factor. For a fixed electrical frequency, more pole pairs mean a lower shaft speed. Enter the wrong number and the controller misjudges that ratio, so the shaft runs at the wrong speed.

Why is the pole count always an even number?

Magnetic poles come in north and south, and each must have a partner, so they appear in pairs. That makes the total an even number. You will see 2, 4, 6, 8 poles, but never an odd count like 3 or 5.

Tags:CommutationFundamentalsMotor Poles