Skip to content

Solo Pro 400-160

SOLO PRO 400-160

45kW – 150 to 450V – 160A

Part Number: SOLO_PRO_400_160
Control Module: SOLO SOM
Form Factor: Four-point wall or frame mount

Coming Soon

Talk to an engineer

SOLO PRO 400-160, angle view

The High-Voltage Powerhouse

A complete 150–450 VDC, 160 A motor drive in a sealed, liquid-cooled IP67 housing. With 45 kW continuous output, EtherCAT and CANopen, isolated Safe Torque Off and a dual-core SOLO SOM inside, the SOLO PRO 400-160 is built for traction, AGVs, heavy machinery and harsh environments.

EtherCAT, CANopen, UART and USB

Specifications

What Generation PRO Adds

  • EtherCAT on board

    Two ports on every unit, daisy-chained without a switch. CANopen, USB and UART stay where they are.

  • Absolute feedback

    BiSS-C and Sin/Cos join Hall and incremental: the motor knows its angle at power-on, with no homing move.

  • Two encoders at once

    One on the motor, one after the gearbox. A slipped coupling shows up as a difference between them.

  • A core for your code

    One core runs the SOLO motion firmware. The second one is yours, in C, over JTAG and SPI.

Specifications

Power Rating

ParameterUnitRate
DC Bus Supply VoltageVDC150 to 450
Logic-Side Supply Voltage (isolated)VDC11 to 28
Max continuous DC CurrentADC160
Max continuous AC CurrentArms100
Max continuous PowerkW45
Peak Output PowerkW—
Internal Bus CapacitanceµF330

Performance

ParameterUnitRate
Switching FrequencyKHz8 to 80
Current Loop ExecutionµS7
Speed/Position Loop SamplingµS500
Speed/Position Loop ExecutionµS75
Current ResolutionmAContact Solo
Max Incremental Encoder FrequencyMHz10
Absolute Encoder (BiSS-C) Clock FrequencyMHz2 (min) to 8 (max)

Regenerative Braking

ParameterUnitRate
Brake Chopper—Not Available
Regenerated Energy—Absorbed by the Supply or Battery
Motor Support & Control Modes

MOTOR COMPATIBILITY

  • All Motor Types (DC/BLDC/PMSM/EC)

    Up to 160A DC (100 Arms)

CONTROL METHODS

  • Sensor-Based Control

    Yes

  • Sensorless Control

    —

CONTROL FEATURES

  • Torque Control

    Yes (closed loop, FOC)

  • Speed Control

    Yes (closed loop)

  • Position Control & Embedded Profile Engine

    Yes (embedded S-curve, position & speed)

  • Automatic Motor Identification & Self-Tuning

    Yes

  • FOC Loop Rate

    ≈ 140 kHz

  • Modulation

    Space Vector Modulation (SVM)

  • Regenerative Operation

    Four-quadrant

DUAL-CORE ARCHITECTURE (SOLO SOM)

  • Motion Core

    SOLO production motor-control firmware (FOC, protections, EtherCAT, CANopen)

  • User Core

    Optional open processor for user applications

I/O & Position Sensing

ANALOGUE I/O

  • Analogue Command Inputs (AI1_IN, AI2_IN)

    0 – 5V analogue or PWM above 5 kHz (2 Inputs)

  • Analogue Outputs

    None

DIGITAL I/O

  • General-Purpose I/O (GPI/O1, GPI/O2)

    2 (0 – 5V)

HALL SENSOR POSITION FEEDBACK

  • Presence

    Yes (digital Hall, 0 – 5V)

INCREMENTAL ENCODER

  • Encoder Type

    Differential (up to 12V input)

  • Max Encoder Frequency

    10 MHz (pre-quadrature)

ABSOLUTE ENCODERS

  • BiSS-C Absolute Encoder

    Primary (12V input, +5V / 200 mA switched supply)

  • BiSS-C Clock Frequency

    2 MHz (min) to 8 MHz (max)

  • Sin/Cos Absolute Encoder

    Yes (max 4.5V continuous)

TEMPERATURE SENSING

  • User PT1000 (J3)

    Yes (general purpose, 3.3V max)

  • Motor PT1000 (J13)

    Yes, isolated, trip at 120 °C

  • Internal Base-Plate NTC

    Built in, trip at 85 °C

AUXILIARY OUTPUTS

  • +5V_Ext. Auxiliary Output

    5V / 1A (5W), 2A e-fuse protected

Communication & Interfaces

ETHERCAT

  • Presence

    Yes, 2 ports (PHY0 / PHY1 on J3), daisy-chain without external switch

  • PHY

    2 × 100BASE-TX

  • Isolation

    External isolating LAN transformer required (no RJ45 on the drive)

CANBUS (CANOPEN DS402)

  • Presence

    Yes (CANH / CANL on J3)

  • Speed

    Classical CAN up to 1 Mbit/s

  • Isolation

    Isolated control side (GND_ISO), not isolated from the logic supply

  • Node ID / Bit Rate

    Set via Motion Terminal or CANopen LSS

USB

  • Presence

    Yes

  • Connector

    Sealed USB 2.0 Type-C (Virtual COM Port)

  • Isolation

    Control side, referenced to GND_ISO

UART / SPI

  • Presence

    Not available

Electrical Safety & Protection

HARDWARE PROTECTIONS

  • Motor-Phase Over-Current

    250A

  • DC Bus Over-Current

    125A

  • Over-Voltage

    450V

  • Under-Voltage

    150V

  • Motor Over-Temperature (PT1000)

    120 °C

  • Base-Plate Over-Temperature (NTC)

    85 °C

  • Reverse Polarity

    —

FUNCTIONAL SAFETY

  • Safe Torque Off (STO)

    Dual channel (STO1/STO2), optically isolated, with feedback output

  • Safe Brake Off (SBO)

    Not available

GALVANIC ISOLATION

  • Control & I/O Side vs. Power Stage

    Isolated (logic supply must be galvanically isolated from the DC bus)

Physical

SIZE & WEIGHT

  • Dimensions (WxDxH) mm

    316 x 220.5 x 107 mm

  • Dimensions (WxDxH) in

    12.44 x 8.68 x 4.21 in

  • Body Size (excl. tabs) mm

    262 x 217 mm (WxD)

  • Weight

    —

MOUNTING

  • Mounting

    Four-point wall or frame mount, 4 × Ø6.5 mm holes

  • Mounting Hole Pattern

    289 x 120 mm

  • Hole Height Above Base Plane

    24 mm

THERMAL MANAGEMENT

  • Cooling

    Liquid, serpentine channel in the base plate (mandatory, never run without coolant flow)

  • Board Temperature

    -20 to +120 °C

  • Base-Plate Temperature

    -20 to +85 °C

  • Ingress Protection

    IP67 (with mating connectors fitted)

  • Coolant Type / Flow Rate / Inlet Temperature

    —

Certifications & Tests

Certification / TestStandard / Compliance Reference
Radiated Emissions - Enclosure PortCISPR 16-2-3 EN 55016-2-3 [Class B]
Enclosure Ports - Radio-Frequency Electromagnetic Field (AM)IEC / EN 61000-4-3 [Class B]
I/O DC Power Ports - Radio-Frequency Common ModeIEC / EN 61000-4-6 [Class B]
Enclosure Ports - Electrostatic DischargesIEC / EN 61000-4-2 [Class B]
I/O DC Power Ports - Fast TransientsIEC / EN 61000-4-4 [Class B]
I/O DC Power Ports - SurgesIEC / EN 61000-4-5 [Class B]
Enclosure Ports - Power-Frequency Magnetic FieldIEC / EN 61000-4-8 [Class B]
Ingress ProtectionIEC / EN 60529 [IP67]
RoHS2011/65/EU

Interested In The SOLO PRO 400-160?

Tell us about your motor and your application: we will come back to you with availability and timing.

By submitting you agree to our Privacy Policy. We use your data only to answer your request.